Version 3.5 S22 --------------- - ADDED: QWave IO server Version 3.5 S20 --------------- - ADDED: inf ComCfg PPPAnswRing: Number of reings before the eWON answers PPPSrvDialInWD: Maximum number of hours the eWON can wait before a successfull incoming call occures, reset otherwise. - ADDED: Modbus advanced paramter MbsGwPrio: if 1 means modbus gateway request have equal priority over internal eWON Modbus requests (default value is 0). Version 3.5 S19 --------------- Added: - Port 8080 added for HTTP server Bugfix: - Timing adjustment for TAP to Semascript servers - Incorrect response when routing XIP to unitelway to another unitelway slave Version 3.5 S18 --------------- Bugfix: - Timing adjustment for TAP to Semascript servers Version 3.5 S17 --------------- Bugfix: - tap7e1 protocol not correctly parsed Version 3.5 S16 --------------- - Possibility to send SMS to TAP server using 7e1 byte config. The syntax is defined consists in replacing "tap" protocol by "tap7e1" Possibility to send Semascript/ SemaDigit to BENELUX Semaphone using the Belgacom server: Sending a semadigit to 0498373101 you must call the server at phone number 0458500001 (0+0458500001 if you must first dial a 0 on a PABX) keep only the last 7 digits of the semaphone and use TAP protocol with 7e1 (case sensitive, 7E1 would not work) sendsms "8373101,tap7e1,0458500001","023891131" if the eWON is behind a PABX and 0 must be dialed first use sendsms "8373101,tap7e1,0+0458500001","023891131" Version 3.5 S14 --------------- Bug fix: * Diagnose reporting problem when doing a full reset. Version 3.5 S13 --------------- Bug fix: * Transparent forwarding did not work for ports over 81 Version 3.5 S12 --------------- Bug fix: Alarm message reported the last tag value before alarm occured (except when predelay was used). Now the actual tag value is sent in the alarm message. New feature: A basic function called DYNDNS has been added. This function can be used to synchronize No-Ip with the eWON PPP IP address. This command starts a dialout if required. version 3.5 S10 -------------- - Added 2 modifiers for reading modbus registers, currently the following modifiers are available: L: read 2 regs R1, R2 as a LONG R1 is Less significant, R2 is most significant M: read 2 regs R1, R2 as a LONG R2 is Less significant, R1 is most significant NEW D: read 2 regs R1, R2 as a DWORD R1 is Less significant, R2 is most significant E: read 2 regs R1, R2 as a DWORD R2 is Less significant, R1 is most significant NEW F: read 2 regs R1, R2 as a FLOAT R1 is Less significant, R2 is most significant H: read 2 regs R1, R2 as a FLOAT R2 is Less significant, R1 is most significant I: read 1 register considered as 16 bits signed integer W: read 1 register considered as 16 bits unsigned integer (default) Version 3.5 S8-S9 ----------------- Added FastSrv mode for modbus tag access. version 3.5 S7 -------------- - When eWON boots, the first LI counter period is not optimised, it may be longer than a standard period. In this release the first period will be as short as possible to return to normal operation quickly - 600 baud has been added to valid baurates in Modbus IO server (and so also for Basic access) - The maximum number of requests that can be read was limited to 25 It has been increased to 125 (modbus standard) - Then pulse with for eWON 1000 was limited to 65535, this value has been increased to 2147483647 - In some case the GSM modem was not reponding any more and reset did not bring it back. This release performes a software reset of the GSM during init and the ModExp param in the config allows garanties that eWON will not work without the modem up and running. version 3.5 S5 -------------- - Max Energy pulse length now limited to 268435455 instead of 65535 - First energy period now equals rest of a normal period until a new period begins (always less than defined interval) version 3.5 S4 -------------- NEW FEATURES ONLY - Dialout: Hang up if no action in progress since X minutes (-1 not used, 0 immediate, X minutes). Comcfg.txt Config parameter is "HUNoAct" Parameter is accessible through Config/System/Com/Dialup (PPP) page - Dialout: Max Call Duration Comcfg.txt Config parameter is "MaxCallDur" Parameter is accessible through Config/System/Com/Dialup (PPP) page - X25 connection script to SITA network Parameters for X25 connection script are only available in comcfg.txt X25Net:1 X25Usr: Must contain UserName X25Facil: Must contain Password X25X121: Must contain X121Address - When the modem fails too many times to connect (for dialout) perform a hardware reset of the modem. A parameter defines the maxium number of errors before the modem is reset if it fails to dialout at the telephone network level. This means that error at the PPP level are not taken into account by this error counter. Comcfg.txt Config parameter is "DOErrRst" (default value is 4) Parameter is not accessible through web configuration version 3.5 S3 -------------- - The comcfg.txt file from the COM configuration (can be read using an ftp client connected to the eWON) can now be dropped back to the eWON using an FTP client in order to update only the eWON COM config. - The maximum number of different IP that can be polled by modbus has been increased to 20 - UNITE IO Server When SWx tags where defined with type modifier set to W (it is the default) the creation was refused with error "Invalid IO name for Tag" - The H type modifier can now be used to address reverse floats in Modbus. The default float are read with F modifier. example: 40001F,4 version 3.5 S2 -------------- - Fixed a stability issue in eWON operating system. Sometimes the eWON was reformated unexpectedly after a reboot. The problem occured more often when working with files in the \usr directory. version 3.5 S1 -------------- - Modbus TCP: when polling tags in Modbus TCP with the modbus IO server, connection can fail with message "socket connection failed" - The default value for UniTE IO server "Master response timeout" as been changed to 1000 MSec and maximum value has been changed to 3000 MSec - Writing to UNITE tag with type modifier set to I or L cause the eWON to crash. - The PDA Web site has been reviewed and updated to be compliant with PocketPC and other PDA devices including Sony Ericsson P800